|  | The influence of a humidity dependent vapour retarder on the annual moisture distribution in thermally insulated flat roof constructions has been investigated by means of long term in situ measurements and two numerical simulation methods. Based on both measurements and transient numerical simulations, the role of the vapour retarder for this type of constructions has been evaluated. Further investigations on other types of vapour retarders and the influence of other parameters such as tilt angle of the roof, location and insulation products are running. |
 |
| |
| |
 |
|
|
|
|